nc_program_manager/.paul/STATE.md
dtrentin 9bb65c4748 docs(paul): unify phase 5 and close v0.1 milestone
Phase 5 (NC Validator) UNIFY complete.
v0.1 Multi-CN Release milestone closed — all 5 phases done.

- 05-01-SUMMARY.md: NcProgramValidator + 30+ tests documented
- ROADMAP.md: all phases marked complete, v0.2 scope drafted
- PROJECT.md: requirements evolved, tech stack updated to 4 manufacturers
- STATE.md: milestone 100%, loop closed, next action documented

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-05-17 22:19:50 +02:00

3.6 KiB

Project State

Project Reference

See: .paul/PROJECT.md (updated 2026-05-17)

Core value: Machinists transfer CNC programs to/from any controller without manual steps or internet Current focus: v0.1 complete — ready for next milestone planning

Current Position

Milestone: v0.1 Multi-CN Release — COMPLETE Phase: 5 of 5 — Complete Plan: All plans unified Status: Milestone complete, ready for v0.2 planning Last activity: 2026-05-17 — Phase 5 unified, milestone closed

Progress:

  • Milestone v0.1: [██████████] 100%

Loop Position

Current loop state:

PLAN ──▶ APPLY ──▶ UNIFY
  ✓        ✓        ✓     [Loop complete — milestone done]

What Was Built (v0.1 Multi-CN Release)

Phase 1 — CNC Abstraction

  • Namespace: Fanuc_integration.Cnc.*FanucProgramManager.Cnc.* (29 files)
  • IFocasDialect extended: UploadStart/DownloadStart accept short fileType
  • IFanucMachine created: extends ICncMachine with tool offset + work zero R/W
  • CncManufacturer enum: Fanuc, Heidenhain, Siemens, Mitsubishi
  • All 29 Cnc/**/*.cs files added to csproj

Phase 2 — Heidenhain LSV2

  • HeidenhainConnectionConfig — IP, port 19000, credentials, timeout
  • Lsv2Client — TCP framing, CRC-16/CCITT, login (SELECT+LOG_IN), ReceiveFile/SendFile
  • HeidenhainMachine : ICncMachine — RunGuardedAsync pattern, state machine

Phase 3 — Siemens + Mitsubishi FTP

  • SiemensConnectionConfig / SiemensFtpClient / SiemensMachine : ICncMachine
  • MitsubishiConnectionConfig / MitsubishiFtpClient / MitsubishiMachine : ICncMachine

Phase 4 — Wiring

  • CncMachineFactory — creates right ICncMachine from InputArgs
  • InputArgs — added manufacturer, username, password fields
  • Program.cs — full rewrite using ICncMachine; Fanuc 3-file via IFanucMachine cast

Phase 5 — NC Validator

  • ValidationSeverity / ValidationError / ValidationResult model types
  • INcProgramValidator + NcProgramValidator (5 universal + per-manufacturer rules)
  • Validator injected into all 4 machine classes; upload blocked on Error severity
  • NcProgramValidatorTests — 30+ NUnit tests

Test Infrastructure

  • FanucProgramManager.Tests/ — NUnit 3.13.3 + Moq 4.18.4, .NET 4.7.2
  • FtpServerStub + Lsv2ServerStub — in-process TCP stubs
  • Unit + integration tests; Fanuc FOCAS tests [Ignore]d (Windows-only DLL)

CLI Args (v0.1)

  • -manufacturer=fanuc|heidenhain|siemens|mitsubishi (default: fanuc)
  • -username= (Heidenhain/Siemens/Mitsubishi)
  • -password= (Heidenhain/Siemens/Mitsubishi)

Accumulated Context

Decisions

  • .NET 4.7.2 locked — max compatibility
  • Offline-only license check (AES, unchanged)
  • Heidenhain: LSV2 port 19000, needs real hardware testing
  • Siemens: FTP /_N_MPF_DIR/, needs Sinumerik FTP option enabled on machine
  • # = Warning in Fanuc/Mitsubishi — macro variable indicator
  • Constructor injection for validator: internal ctor accepts mock — testability without Windows DLL

Deferred Issues

  • License system: hardcoded AES key/IV — v0.2 target (hardware fingerprint + encrypted file)
  • Heidenhain: ReadActiveProgramAsync / SelectMainProgram not implemented
  • Siemens: same as Heidenhain
  • Build + integration not verifiable on Linux (fwlib32 Windows-only)

Blockers/Concerns

None — code complete, pending hardware testing on real machines.

Session Continuity

Last session: 2026-05-17 Stopped at: v0.1 milestone UNIFY complete Next action: /paul:plan for v0.2 License System, or /paul:milestone to define next milestone Resume file: .paul/ROADMAP.md


STATE.md — Updated after every significant action