What
Field testing against a local docker FTP server surfaced 3 bugs that blocked every Fanuc/Mitsubishi program upload. All fixed + field-verified end-to-end.
lines[0], butFanucProgram.Standardize()prepends\n-> always failed "First line must be O####". Now scans first non-blank line..batpassed-pathprogrammaunquoted -> truncated at first space on install paths with spaces. Quoted in all 7 scripts.WriteProgramAsyncresolved-pathas a directory ("1" -> "1/O0001"), while read used "/PRG/1" -> STOR failed with "unable to connect to remote server". Write now resolves identically to read (per NC Explorer manual IB-1500904: PRG/USER/, no extension).ResolvePathsimplified to single-arg.Tests
Still open (logged in .paul/ISSUES.md)
ISS-020 Siemens/Fagor (extension coupling + ISS-013); C5 download wrapper format; ISS-017 wrong-creds diagnostic.
Commits:
85d0b57,4067366ISS-018: FanucProgram.Standardize() prepends a leading '\n' to the program body, so the O#### header is not on lines[0]. The validator first-line check read lines[0] and always failed "First line must be O####", rejecting every valid Fanuc/Mitsubishi upload. Scan the first non-blank line instead. Upload (FOCAS tape) format unchanged. ISS-019: field-test .bat files passed -pathprogramma unquoted; on install paths with spaces ("visual studio prove") cmd split the arg and ArgParser captured only the first token -> truncated path. Quote the arg in all 7 scripts. Add regression test Validate_LeadingBlankLineBeforeONumber for both Fanuc and Mitsubishi. Surfaced by field testing against a local docker FTP server. Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>WriteProgramAsync resolved -path as a directory and combined it with program.Name ("1" + "O0001" -> "1/O0001"), while ReadProgramAsync resolved it as a program identifier under ProgramDirectory ("1" -> "/PRG/1"). The write target therefore never matched the read target: STOR went to a nonexistent relative dir and failed with "unable to connect to remote server" (-204). Surfaced once ISS-018/019 stopped masking it. Per Mitsubishi NC Explorer manual IB-1500904, programs live under PRG/USER and are addressed by their program name/number with no extension. Resolve write the same way as read: ResolvePath is now single-arg (path = identifier or full path, joined with ProgramDirectory). program.Name is used for validation only. Update write unit test to the symmetric contract and add a roundtrip regression test (-path "1" -> /PRG/1). Siemens/Fagor share the pattern but tie extension handling to name (entangled with ISS-013); left open in ISS-020. Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>