Commit graph

2 commits

Author SHA1 Message Date
Trentin Davide
4067366d06 fix(mitsubishi): symmetric read/write FTP path (ISS-020)
WriteProgramAsync resolved -path as a directory and combined it with
program.Name ("1" + "O0001" -> "1/O0001"), while ReadProgramAsync
resolved it as a program identifier under ProgramDirectory ("1" ->
"/PRG/1"). The write target therefore never matched the read target:
STOR went to a nonexistent relative dir and failed with "unable to
connect to remote server" (-204). Surfaced once ISS-018/019 stopped
masking it.

Per Mitsubishi NC Explorer manual IB-1500904, programs live under
PRG/USER and are addressed by their program name/number with no
extension. Resolve write the same way as read: ResolvePath is now
single-arg (path = identifier or full path, joined with
ProgramDirectory). program.Name is used for validation only.

Update write unit test to the symmetric contract and add a roundtrip
regression test (-path "1" -> /PRG/1).

Siemens/Fagor share the pattern but tie extension handling to name
(entangled with ISS-013); left open in ISS-020.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-02 09:57:10 +02:00
dtrentin
a5d73db69a refactor(rename): FanucProgramManager → NcProgramManager
Phase 06 complete:
- Namespace renamed in 62 .cs files (namespace + using directives)
- AssemblyName + RootNamespace updated in csproj files
- FanucProgramManager.csproj → NcProgramManager.csproj
- FanucProgramManager.sln → NcProgramManager.sln
- FanucProgramManager.Tests/ → NcProgramManager.Tests/
- FANUCMachine.cs deleted (dead code, zero references)

Fanuc-prefixed class names kept (FanucMachine, FanucProgram,
IFanucMachine) — manufacturer identifiers, not project names.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-05-17 22:31:36 +02:00
Renamed from FanucProgramManager.Tests/Unit/MitsubishiMachineTests.cs (Browse further)